Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Language
Document Type
Year range
1.
American Journal of Respiratory and Critical Care Medicine ; 205(1), 2022.
Article in English | EMBASE | ID: covidwho-1927925

ABSTRACT

Introduction: PrecISE is an ongoing Phase II clinical trial sponsored by the National Heart, Lung, and Blood Institute to investigate the efficacy of several treatments for severe asthma. The threat of COVID-19 has raised interest in obtaining reliable spirometry data for asthma research and clinical care in a remote, “no-touch” fashion. Prior studies of the accuracy of remote spirometry have not included real-time coaching. The PrecISE investigators hypothesized that remote spirometry with real-time video coaching could provide an accurate FEV1 for use as a study endpoint in a clinical trial setting. Methods: PrecISE network participants had remote spirometry post-bronchodilator (4 puffs of albuterol) measured with video coaching from trained research coordinators using the ZEPHYRx platform connected to MIR Spirobank Smart handheld spirometers. Remote spirometry measurements occurred within a +/- 3-day window from scheduled in-person PrecISE visits during which in-person spirometry with bronchodilator challenge was measured with standard equipment (Vyaire Medical). All measurements occurred during the screening/run-in period of the PrecISE protocol. Both remote and in-person spirometry was overread by the PrecISE Spirometry Core and only included in analysis if sessions met ATS acceptability and reproducibility criteria. Correlations between remote and in-person FEV1 and FVC were analyzed, and Bland-Altman plots generated. As a comparison, within subject biological variability was measured using data from separate in-person visits during the screening/run-in period. Results: A total of 128 pairs of remote/in-person spirometry data were obtained. The mean FEV1 for remote spirometry was 2.50 L (SD 0.81) and for inperson spirometry was 2.42 L (SD 0.80), with an estimated correlation of 0.95 (95% CI: 0.93, 0.97). The mean difference in FEV1 (in-person - remote) was -0.07 L (95% CI: -0.11, -0.03, SD 0.25). The mean FVC for remote spirometry was 3.72 L (SD 1.01) and for in-person spirometry was 3.53 L (SD 0.93), with an estimated correlation of 0.91 (95% CI: 0.87, 0.93). The mean difference in FVC (in-person - remote) was -0.19 L (95% CI: -0.27, -0.12, SD 0.42). A total of 142 pairs of repeated in-person spirometry measurements were performed (median time between measurements: 43 days), with mean difference in FEV1 of -0.01 L (95% CI: -0.06, 0.03) and FVC of -0.02 L (95% CI: -0.07, 0.03). Bland-Altman plots for FEV1 differences are shown in Figure 1. Conclusions: Remote spirometry with real-time video coaching provides a reliable FEV1 measurement which correlates closely with in-person spirometry and is suitable for use in clinical trials. (Figure Presented).

SELECTION OF CITATIONS
SEARCH DETAIL